Description

The PT300 intelligent pressure switch is an intelligent digital display pressure measurement and control product integrating pressure measurement, display, and output control. The product is a fully electronic structure, which measures and controls the pressure of the control system. The intelligent pressure switch is flexible to use, simple to operate, easy to debug, safe and reliable. Widely used in hydropower, tap water, petroleum, chemical, machinery, hydraulic and other industries to measure, display and control the pressure of fluid media

Technical Parameters

Parameter

Parameter Value

Parameter

Parameter Value

Measuring Range

-0.1~0-0.02~100MPa

Measurement Accuracy

≤±0.25%,0.5%FS

Stability

≤0.2% /year

Display Method

4-digit digital tube unit display

Type of pressure

Gauge pressure, absolute pressure, sealed gauge pressure

Display range

-1999~9999

Overload capacity

1.5times full scale

Maximum power consumption

≤1W

Power supply

15~36V.DC

PL

IP65

Switch load capacity

<1.2A(24V.DC)

Output form

2 switch quantity(PNP/NPN)+4~20mA

Load resistance

≤(U-12)/0.02Ω

Switch life

>10years

Response time

≤5ms

Medium temperature

-40℃~85℃

Ambient temperature

-40℃~70℃

Relative temperature

0~95%

Storage temperature

-20℃~60℃

Temperature effect

Within the specific working temperature,the output change≤±0.05% of the range for every 10℃ change in the ambient temperature

Dimensions & Attention

product-531-460

SELECTION GUIDE

SeriesGuide PT300XXXXXXX
Pressure CategoryGaugeG      
Absolute PressureA
Pressure CategorybarB
MPaM
kPaK
Pressure rangePressure Range Value xX
Process ConnectionG1/4G1/4
1/4NPT1/4NPT
G1/2G1/2
M20×1.5M20
R1/4R1/4
R1/2R1/2
1/2NPT1/2NPT
Output Signal1 channel PNP+4-20mA outputH1
2 channel PNP outputH2
2 channel PNP+4-20mA outputH3
1 channel NPN+4-20mA outputH4
2 channel NPN outputH5
2 channel NPN+4-20mA outputH6
Accuracy Class0.5%FS
0.25%FS2A
Special RequirementPlease consult for other special requirem

PRECAUTIONS

1) When installing the connecting cable, the power supply 24VDC to the instrument should be separated from the electrical cable, and try to avoid parallel wiring at close distances.

2) Based on the anti-interference principle of digital circuit AD sampling, we solemnly remind users that the alarm speed of the switch is not as fast as possible. The choice of the alarm speed should be based on the need, in the balance between speed and stability. When the alarm speed is selected quickly, accidental fluctuations in the pressure signal or accidental interference burrs on the power supply may cause frequent alarms after being collected by the digital circuit. When the alarm speed is selected relatively slowly, the digital circuit can have sufficient time to correct The signal is subjected to interference removal filtering, and the stability can be greatly improved.

Operation & Maintenance

Operation:

1. The user can put into operation without any adjustment of the pressure switch. Beforethe  operation, check whether the installation and electrical connection are correct, turn on the power, and put it into operation.
2. The pressure switch can work when the power is turned on, and the output signal is stable and reliable.

Maintenance:

The pressure switch is a high-precision measuring instrument. In daily maintenance, check whether the cable sheath is aging and cracked, and whether there is water ingress. If the pressure hole is blocked or the diaphragm is fouled, please clean it with a solvent compatible with the material of the pressure switch structure. Do not use a wire to poke the pressure hole or brush the diaphragm.

Video

Send Inquiry

    Reviews

    There are no reviews yet.

    Be the first to review “Digital Pressure Switch”

    Your email address will not be published. Required fields are marked