Description

Ziasiot Mass Flow Meter supports flow ranges from 0.5SCCM to 5000SLPM, pressures from 5KPaA to 2MPaA, and temperatures from -50 to 110℃. It can switch between more than 70 single media and mixed working fluids in real time and provides more than 10 digital/analog communication methods. Currently, it has formed a variety of general-purpose laminar flow differential pressure flowmeter/controller specifications, such as S/P/SC, which can meet the various flow control needs of high-end customers in semiconductors, new energy, new materials, and other industries.

Features

Based on patented internally compensated laminar flow differential pressure technology, the Ziasiot laminar mass flow meter incorporates pressure and temperature sensors. It effectively compensates for differences in volumetric flow rate and mass flow rate caused by temperature and pressure, enabling rapid and accurate measurement of five key parameters of process gases: real-time temperature, pressure, operating flow rate, standard flow rate, and cumulative flow rate. Whether you require precise and rapid measurement of gas flow, leak rate monitoring, or use as a standard meter for measurement value transfer and calibration, Ziasiot flow meters can provide you with the optimal solution.

The mass flow meters have the characteristics of high precision, high sensitivity, strong anti-interference and good repeatability in the range.

Parameters

E Series Mass Flow Meter
ModelE100E200E300E400E450
Flow range20SCCM~500SLPM10SCCM~500SLPM0.5SCCM~5000SLPM2SCCM~2000SLPM2SCCM~2000SLPM

Accuracy

±1.0%F.S. (2%~100% F.S.)

±1.0%Rd(30%~±100%F.S.) ±0.3%F.S.(1%~30%F.S.)

±1.0%Rd(20%~100%F.S.
 ±0.2%F.S.(0.5%~20%F.S.)

±1.0%Rd(10%~100%F.S.)
±0.1%F.S.(0.5%~10%F.S.)

±0.5%Rd(20%~100%F.S.)
±0.1%F.S.(0.5%~20%F.S.)

Repeatability±0.2%F.S.

±0.2%Rd(20%~100%F.S.
 ±0.04%F.S.(0.5%~20%F.S.)

±0.1%Rd(20%~100%F.S.)
  ±0.02%F.S.(0.5%~20%F.S.)

Pressure shift

≤±0.1%F.S./100kPa(Benchmark 100kPaA)

≤±0.1%Rd/100kPa(Benchmark 100kPaA)

Temperature shift

≤±0.05%F.S./℃(Benchmark 25℃)≤±0.02%F.S./℃(Benchmark 25℃)
Operating range2%~100%F.S.1%~100%F.S.0.5%~100%F.S.
Response time≤100ms
Warm-up time≤1s
Gas temperature0℃~50℃-20℃~60℃
Ambient temperature0℃~50℃-20℃~60℃
Pressure drop

12kPa(≤5SLPM);60kPa(10SLPM);8kPa(20~50SLPM);10kPa(100SLPM);
15kPa(200SLPM); 19kPa(500SLPM);23kPa(1000SLPM);22kPa(1500~2500SLPM);35kPa(3000~5000SLPM)

Proof pressure1.5 MPaA
Max pressure900kPaA
Leak rate≤1×10-10 Pa·m³/s He
Power supply voltage24VDC(±20%)
Current consumption<150mA(<3.6W)
Mounting orientation sensitivityNone
Process connectorsG thread、VCR、Swagelok、IGS
Wetted materialsSUS316L、FKM、FFKM、EPDM、Neoprene
SealingRubber ring seal:FKM、FFKM、EPDM、Neoprene
CommunicationRS485、PROFIBUS、EtherCAT,PROFINET,DeviceNet、4~20mA / 0~5V
P Series Mass Flow Meter
ModelP300P400P450
Flow range0.5SCCM~5000SLPM2SCCM~2000SLPM2SCCM~2000SLPM

Accuracy

±1.0%Rd(20%~100%F.S.);
±0.2%F.S.(1%~20%F.S.)

±1.0%Rd(10%~100%F.S.);
±0.1%F.S.(0.5%~10%F.S.)

±0.5%Rd(20%~100%F.S.);
±0.1%F.S.(0.5%~20%F.S.)

Repeatability

±0.2%Rd(20%~100%F.S.);
 ±0.04%F.S.(0.5%~20%F.S.)

±0.1%Rd(20%~100%F.S.);
±0.02%F.S.(0.5%~20%F.S.)

Pressure shift

≤±0.1%Rd/100kPa(Benchmark 100kPaA)

Temperature shift

≤±0.02%F.S./℃(Benchmark 25℃)
Zero shift±0.1%F.S.
Operating range0.5%~100%F.S.
Response time≤100ms

Warm-up time

≤1s
Gas temperature-20℃~60℃
Pressure drop

7kPa(≤20SLPM);9kPa(50~100SLPM);12kPa(200SLPM);
17kPa(500SLPM);20kPa( 1000SLPM);22kPa(1500~2500SLPM);35kPa(3000~5000SLPM)

Proof pressure1.5 MPaA
Max pressure900kPaA
Endurance time15 hours
Mounting orientation sensitivityNone
Process connectorsG thread
Wetted materialsSUS316L、FKM
SealingFKM
CommunicationRS485
S Series Mass Flow Meter
ModelS100S200
Flow range0.5SCCM~5000SLPM0.5SCCM~2000SLPM

Accuracy

±1.0%Rd(20%~100%F.S.)
±0.2%F.S.(1%~20%F.S.)

±0.5%Rd(20%~100%F.S.)
±0.1%F.S.(1%~20%F.S.)
Repeatability±0.2%F.S.

Pressure shift

Zero:≤±0.2%F.S./100KPa;

Span:≤±0.2%F.S./100Kpa(Benchmark 100KPaA)

Zero:≤±0.05%F.S./100KPa;

Span:≤±0.05%F.S./100Kpa(Benchmark 100KPaA)

Temperature shift

Zero:≤±0.05%F.S./℃;

Span:≤±0.05%F.S./℃(Benchmark 25℃)

Zero:≤±0.02%F.S./℃;

Span:≤±0.02%F.S./℃(Benchmark 25℃)

Operating range1%~100%F.S.
Response time≤100ms
Warm-up time≤1s
Gas temperature-20℃~60℃
Pressure drop4kPa(≤5SLPM); 8kPa(10~500SLPM); 15kPa(1000~5000SLPM)
Proof pressure1.5 MPaA
Max pressure60kPaA~1MPaA
Power supply voltage24VDC(±20%)
Mounting orientation sensitivityNone
Process connectorsG thread
Wetted materialsSUS316L
Sealing materialRubber ring seal: FKM
CommunicationRS485, 0~5V, 4~20mA

Application

It is suitable for small flow measurement of various gases
1. Oxygen 2. Air 3. Methane 4. Argon 5. Nitrogen 6. Helium 7. Sulfur dioxide 8. Ethane 9. Carbon dioxide 10. Hydrogen 11. Compressed air 12. Natural gas

Send Inquiry